DEFI Xpress 360 Joules Biphasic Defibrillator Pacer Rapid Defibrillation

DEFI Xpress 360 Joules Biphasic Defibrillator Pacer Rapid Defibrillation DEFI Xpress 360 Joules Biphasic Defibrillator Pacer Rapid Defibrillation

Defibrillation Monitor is a safe, easy to use defibrillation and monitoring device. The system is an extremely flexible device that integrates manual defibrillation mode, monitoring mode and AED mode.

Quantity:
Share this:
  • Product Description
  • Parameter

360 Joules Biphasic Defibrillator Pacer Rapid Defibrillation Features:

1. With manual defibrillation, automatic external defibrillation (AED), ECG monitoring and other functions, is a professional dual-phase defibrillation monitor, suitable for hospitals and clinics;

2. 8-inch screen showing HR, Lead/Pads, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.

3. Automatic analysis of external defibrillation, can automatically select energy, provide screen display and voice prompt.

4. Built-in battery, can be recharged multiple times.

5. Defibrillation output waveform: biphase waveform

6. 50mm thermal printer provides defibrillation record.

7. The maximum energy in manual mode is 360J

8. 3-lead / 5-lead ECG monitoring, displayed on the screen, providing alarm tips.

9. Optional cardiac pacing function.

360 joules biphasic defibrillator,defibrillator pacer,rapid defibrillation

Specificationpacer (Optional)
TypeVVI
Pulse Typerectangular,constant current
Pulse Amplitude0 to 180 mA±10% or 5 mA (whichever is greater).
Pacing RateVariable from 30 ppm to 180 ppm +1.5% (increments or decrements by a value of 2 ppm)
Multi-Function Electrode (MFE)Padsmultipurpose defibillation/pacing electrodes
PausePacing pulse frequency reduced by a factor of 4 when activated.
Refractory PeriodNC(VVI demand do not have this specification)
Pulse Width(20+ 1.5 ms)
Output ProtectionFully defibrillator protected and isolated
SpecificationEtCO2 (Optional)
Type of sensorBy-pass
Technical principleNon-dispersive infrared gas analysis NDIR
Storage condition-40 °C to 70°C,<90% RH, non-condensing
Operating conditions5°C to 50 °C, 10 to 90% RH, non-condensing
Ambient pressure55-115kPa
Power supply5V±5% (max ripple 200 mVp-p)
TDPTypical value 120mA Excursion calibration typical value 280mA
Range0-19.7% (0-150mmHg,or 0-20kPa)
Resolution0.1mmHg
Accuracy0-40mmHg±2mmHg
41 - 70 mmHg±5% of reading
71 - 100 mmHg±8% of reading
101 - 150 mmHg±10% of reading
Respiratory rate2-150 BPM
Respiratory rate measurement accuracy1% ±1BPM
SpecificationNIBP (Optional)
Measurement unti:mmHg/kPa
Measurement Range:Adult:10~270 mmHg/kPa
Pediatric: 10~200 mmHg/kPa
Neonatal: 10~135 mmHg/kPa
Resolution1 mmHg
Accuracy:Maximum mean error:5 mmHg
Maximum standard deviation:8 mmHg
Type of sensorBy-pass
Technical principleNon-dispersive infrared gas analysis NDIR
Storage condition-40°C to 70°C, <90% RH, non-condensing
Operating conditions5°C to 50°C, 10 to 90% RH, non-condensing
Ambient pressure55-115kPa
Power supply5V±5% (max ripple 200 mVp-p)
TDPTypical value 120mA Excursion calibration typical value 280mA
Range0-19.7% (0-150mmHg,or 0-20kPa)
Resolution0.1mmHg
Accuracy0-40mmHg±2mmHg
41 - 70 mmHg±5% of reading
71 - 100 mmHg±8% of reading
101 - 150 mmHg±10% of reading
Respiratory rate2-150 BPM
Respiratory rate measurement accuracy1%±1BPM
SpecificationSPO2 Moudle (Optional)
Measurement Range:30 ~ 100% ,±2% between 80% ~ 90%,Others +5%
Alarm RangeUser set high limit and low limit
Alarm Accuracy±10 within setting values.
Alarm Time AccuracyLess than 12 sec.
×