High-pressure sterilizer adopts innovative high-performance sterilization techniques, made of 304 stainless steel and is fully covered by high-efficiency jackets to ensure rapid heating and shortening cycle time. This ensures uniform heat distribution and reduces utility consumption of heating and cooling. Chamber design minimizes dead zones to achieve optimal loading and throughput. Designed for steam sterilization of surgical instruments, textiles, clothes, rubber products, metals, plastics, and glassware. They are used in hospitals, including CSSD, operating room.
Medical Floor Loading Fully Automatic Horizontal Autoclave sterilizer Description:
Fully
automatic horizontal autoclave, the pulse vacuum method is adopted to
remove the cold air in the cavity, so that the cold air content of the
steam in the cavity is less, and the sterilization is more reliable. At
the same time, in the sterilization process of the horizontal autoclave
sterilizer, the control system automatically adjusts the steam inlet and
exhaust according to the temperature of the inner chamber. Stainless
steel pipes have no dead Angle to ensure complete drainage. The vacuum
pump of medical steam sterilizer makes 3/4 times of pre-vacuum at the
beginning of the cycle, removing more than 99% of the chamber air,
making the chamber steam have good permeability and more uniform
temperature.
Floor loading sterilizer is mainly used to sterilize
medical and experimental cloth articles, surgical instruments and
instruments in hospital supply room, operating room, pharmaceutical
factory and scientific research laboratory. Sterilization process
automatic control, no supervision, easy to use. Automatic Autoclave has
the drying function to achieve the drying effect of the disinfected
items.
Medical Floor Loading Fully Automatic Horizontal Autoclave sterilizer Features:
1.
The main body consists of an inner layer and an outer layer. The inner
cavity is made of high quality acid resistant 304 stainless steel.
Automatic welding, one-time molding. Horizontal circular chamber +
jacket structure, safety, heat preservation, drying effect is the best.
2.
Adopt plate type cogging type + motor or manual locking door structure,
low fault, reliable; Double doors optional. Simple and safe operation.
3.
The door seal is pneumatic or self-inflating. The sealing strip is made
of excellent heat-resistant silicone rubber with long service life.
4. The control system adopts touch screen and PLC to ensure stable operation and correct temperature detection.
5.
Water, pulse (special for vacuum system), heating, sterilization,
drying process is fully automatic, without manual adjustment.
6.
Built-in high quality vacuum pump, to ensure effective air exclusion, to
obtain the best saturated steam (vacuum system). Unique pulse vacuum
drying process (special for vacuum system), residual moisture less than
0.2%. 1~6 pulses, -0.09mpa (-0.9bar) vacuum, to ensure effective air
exclusion to obtain the best saturated steam (vacuum system special)
7. Built-in high efficiency steam generator, microcomputer temperature control, time saving
8.
Pipeline system is optimized design,SUS304 pipeline, clamp type quick
loading mode. All piping, fittings and components are designed and
installed on one side for greater convenience. Repair and maintenance.
The sterilizer can be mounted against a wall, or two sterilizers can be
used simultaneously. Maintain space to save installation space.
9. Control system: HMI man-machine interface, touch screen + microcomputer.
10.
Built-in micro printer, record the entire sterilization information.
Equipped with standard equipment verification interface;
11. F0 value and temperature time double guarantee sterilization effect, with perfect sterilization record;
12. With program selection, parameter setting, equipment operation, report processing and other functions, traceable;
13.
Multiple safety protection measures; Well-designed fault warning
system, fault information real-time display on the touch screen. After
the sterilization cycle is complete, a beep sound will be emitted and a
message will be displayed on the touch screen.
14.Sterilization process: fabric, instrument, liquid, BD, pressure holding test, custom multiple procedures;
Safety protection:
1.heater protection;
2.prevent dry burning;
3.safety interlocking door;
4.over temperature protection;
5.overvoltage protection;
6.automatic release safety valve;
7.electrical safety protection device.
Main Technical Parameter | |
Design pressure | -0.1~0.3Mpa |
Design temperature | 144℃ |
Working pressure | 0.245Mpa |
Vacuum | -0.086Mpa |
Working Temperature | 105~138℃ |
Temperature Equilibrium | < +2.0℃ |
Water Pressure | 0.1-0.2Mpa |
Compessed air pressure | 0.4-0.7Mpa |
Steam Pressure | 0.3-0.7Mpa |
Power vltage | Three-phase five-wire |
AC 380V 50Hz |
Model&Parameter(Without Pulse Vacuum ) | ||||||
Model | Overall Dimensions L*M*H(mm) | Chamber Size (Φ*L)mm | Steam Consumption (KG) | Water Consumption(KG) | Power(KW) | Net Weight(KG) |
WZQ-80D | 990x640x1680 | Φ420x580 | ≤9 | ≤30 | ≤2+⑨ | 220 |
WZQ-100D | 1160x650x1680 | Φ420x750 | ≤10 | ≤30 | ≤2+⑨ | 250 |
WZQ-120D | 1290x650x1680 | Φ420x880 | ≤11 | ≤30 | ≤2+⑨ | 280 |
WZQ-150D | 1290x690x1680 | Φ472x880 | ≤12 | ≤190 | ≤2+⑫ | 350 |
WZQ-200D | 1560x690x1680 | Φ472x1150 | ≤13 | ≤190 | ≤2+⑫ | 370 |
WZQ-300D | 1430x850x1760 | Φ620x995 | ≤18 | ≤200 | ≤2+⑮ | 450 |
WZQ-400D | 1755x850x1760 | Φ620x1320 | ≤22 | ≤200 | ≤2+⑮ | 510 |
Model&Parameter(With Pulse Vacuum ) | ||||||
Model | Overall Dimensions L*M*H(mm) | Chamber Size (Φ*L)mm | Steam Consumption (Kg) | Water Consumption(Kg) | Power(KW) | Net Weight(KG) |
WZQ-80D | 990x640x1680 | Φ420x580 | ≤10 | ≤30 | ≤2+⑫ | 250/280 |
WZQ-100D | 1160x650x1680 | Φ420x750 | ≤11 | ≤30 | ≤2+⑫ | 280/310 |
WZQ-120D | 1290x650x1680 | Φ420x880 | ≤12 | ≤30 | ≤2+⑫ | 310/340 |
WZQ-150D | 1290x690x1680 | Φ472x880 | ≤13 | ≤190 | ≤2+⑮ | 370/410 |
WZQ-200D | 1560x690x1680 | Φ472x1150 | ≤15 | ≤190 | ≤2+⑮ | 400/440 |
WZQ-300D | 1430x850x1760 | Φ620x995 | ≤20 | ≤200 | ≤2+⑱ | 480/530 |
WZQ-400D | 1755x850x1760 | Φ620x1320 | ≤25 | ≤200 | ≤2+⑱ | 540/590 |