Incubators and radiant warmers are used to maintain the body temperature of newborn infants. This is best done so that the energy expended for metabolic heat production is minimized. The heat output of these devices is usually regulated by servocontrol to keep the skin temperature constant at a site on the abdomen where a thermistor probe is attached.

Quantity:
Share this:
  • Product Description

Brief Introduction:
Two control modes: Air mode and baby mode controlled by micro-computer;
Set temperature, air temperature, baby temperature are displayed separately; Humidity concentration system
Inclination of bassinet is adjustable;
Failure alarm indication;
RS-232 connector;
Oxygen input interface;
Configured with fixed neonate bilirubin phototherapy equipment model: HBXHZ-90 with blue fluorescent lamp as the upper light source; And fixed neonate bilirubin phototherapy equipment model: HBXHZ-90L with LED blue light is optional.
Configured with fixed neonate bilirubin phototherapy equipment with SMD LED blue lights under the bassinet.
With DC motor
Standard Configuration:
Main body, mobile cabinet, temperature controller, baby compartment, I.V. Pole with shelf, Skin temperature sensor, mattress, fixed Neonate Bilirubin Phototherapy Equipment model: HBXHZ-90 with blue fluorescent lamp as the upper light source, fixed Neonate Bilirubin Phototherapy Equipment with SMD LED blue light under the bassinet.
Optional parts:
> 37℃ temperature override mode function, Vertical height adjustment stand(VHA stand), Weighing system, Neonate bilirubin phototherapy equipment model: HBXHZ-90L with LED blue light as upper light source and Disposable skin temperature sensor.
Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Mode of control: Air mode control
Air temperature control range: 25°C -37°C (override mode: 37-39°C is optional)
The temperature difference between incubator temperature and average incubator temperature(under steady temperature condition)≤0.5°C
Temperature uniformity: 0.8°C (mattress is on the horizontal position)
Inclination of the bassinet: ±12°
Noise inside hood: 45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.
The average value of total irradiance for bilirubin Ebi max of phototherapy equipment:
≥ 640pW/cm2 ( XHZ-90 )
≥1300pW//cm2 ( HBXHZ-90L )
Built-in timer range: 0-9999 hrs 59min
Accuracy of weight display: ±1% (equipped weighing system)
Environmental Temperature:
Operating range: 20 °C -30°C (Set temperature should be higher 3°C than the environment temperature)
Ambient air movement rate: <0.3m/s
Product Packaging:
Package: each unit is packed into one carton
Dimension: 1085mm x 640mm x 1120mm