Incubators and radiant warmers are used to maintain the body temperature of newborn infants. This is best done so that the energy expended for metabolic heat production is minimized. The heat output of these devices is usually regulated by servocontrol to keep the skin temperature constant at a site on the abdomen where a thermistor probe is attached.

Quantity:
Share this:
  • Product Description

Brief Introduction:
Two control modes: Air mode and baby mode controlled by micro-computer
Humidity concentration display system
Set temperature, air temperature, baby temperature, humidity concentration are displayed separately;
>37℃ temperature set function;
Failure alarm indication;
Embedded integrated sensor box
Double wall hood, automatic air circulation device;
Inclination of bassinet is adjustable;
RS-232 connector;
Oxygen input interface;
DC motor.
Standard Configuration:
HB-YP910: The hood, the base, the mobile cabinet, the controller, I.V pole, tray.
HB-YP920: The hood, the base, the mobile cabinet, the controller, I.V pole, tray, with Humidity control system.
Optional Configuration:
Fixed neonate bilirubin phototherapy equipment model:HB XHZ-90 (with blue fluorescent lamps);
Fixed neonate bilirubin phototherapy equipment model: HBXHZ-90L (with LED blue lights);
Vertical height adjustment stand (VHA stand), Weighing system , SPO2 and Disposable skin temperature sensor.
Specification:
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA ( HB-YP910 )
Power requirement:AC220V-230V/50Hz or AC110-120V/50-60Hz, 1000VA (HB-YP920)
Mode of control: Air mode and baby mode controlled by micro-computer
Air temperature control range: 25℃ -37℃ (override mode 37-39℃)
Baby temperature control range: 34-37℃ (override mode 37-38℃ )
Accuracy of skin temperature sensor: ±0.2℃
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition)≤0.5℃
Temperature uniformity≤0.8℃ (mattress is on the horizontal position)
Inclination of the bassinet: ±12° la Noise inside hood: 45dB(A)
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, sensor box position alarm and system alarm. (HB-YP920 has low water alarm and tank position alarm)
Humidity display range: 0%RH-99%RH
Accuracy of humidity display: ±5%RH(environment temperature is 25℃ , environment humidity is 45%RH±5%RH)
Environmental temperature:
Operating range: 20℃-30℃ (Set temperature should be higher 3℃ than the environment temperature)
Ambient air movement rate: <0.3m/s
Product Packaging:
Package: each unit is packed into two cartons
Dimension (Main body): 1085mm x 640mm x 910mm
(Cabinet): 1125mm x 665mm x 725mm
Gross Weight (Main body):63Kg (for HB-910)
Gross Weight (Main body):66Kg(for HB-920)
(Cabinet):68Kg

×