QPQ50AB Laboratory Endoscope Bedpan Instruments Washer Disinfector QPQ50AB Laboratory Endoscope Bedpan Instruments Washer Disinfector

The automatic visual glass door is adopted for observing the operation inside the tank. The door can be opened by gently kicking the foot switch.

Quantity:
Share this:
  • Product Description

QPQ50 Laboratory Endoscope Bedpan Instruments Washer Disinfector 


 

1.Perfect medical workers protection

--Auto door, foot switch

The automatic visual glass door is adopted for observing the operation inside the tank. The door can be opened by gently kicking the foot switch.

--Totally-enclosed

Rider wash-disinfection tank adopts totally-enclosed structure to avoid sanitizer odor leakage so that protects the medical workers.

--Automatic adjuvant injection

Medical workers only need to link the adjuvant container with the tank through a container with the tank through a connector to avoid harm that caused from manual adjuvant injection.

 

2.Endoscope protection design

--Leaking test function

The leaking test will finish before the endoscope contacts the liquid and will also keep testing during the operation. The system gives out visual and audible signals and will terminate operation as soon as the leaking value exceeds the setting value.

--Blocking test function

The blocking test will start before the endoscope contacts the liquid and after the operation. The systems gives out visual and audible signals and will terminate operation as soon as the pipe is blocked.

 

3.Self-disinfection function

The self-disinfection program can be started during maintenance or after the termination of operation. This function is design to disinfection for wash-disinfection tank (includes 0.2μm filter) and pipeline.

 

4.Process traceability system

--Process data printing

For filing purpose, the printer will print all of process data timely during the operation.

--Process data management

The system collects information of endoscope and connects the process data with computer managing system to achieve synchronization management of patient and disinfection information.

 

5. 100% wash-disinfection

--Omnibearing wash-disinfection

The tank equipped with rotating nozzle and spray arm to wash the outer surface of the endoscope, in the meanwhile, the circulating water flow keeps flushing the endoscope from inside.

--Endoscope pressure booster pump

It is used for washing of tiny pipe, such as air/water injection nozzle, to reduce the formation probability of bacteria biofilm.

--Sterile water rinse

To avoid secondary contamination caused by unsanitary water, the endoscope. Rider equipped with air drying and alcohol drying for user to select.


 

 

Parameters

QPQ 50A

QPQ 50B

Weight(Kg)

100Kg

110Kg

Water consumption

25L

20L

                 Power supply

220V 50HZ

Power(Kw)

4

4.5

Water  supply

Water pressure Mpa

0.35~0.4

Water hardness

CaCo3 concentration<120mg/L

Water PH value

6.5~9

Water drainage

Upper drainage

Overall size:

94x65x74(cm)


×